Johnson F4B-19 Impeller Pump - 24V - 48LPM - Heavy Duty - Self Priming - Bronze Body - 1/2" BSP, 1" Hose - 10-24689-02 (132174)

  • Johnson SPX
    • Johnson F4B-19 Impeller Pump - 24V - 48LPM - Heavy Duty - Self Priming - Bronze Body - 1/2" BSP, 1" Hose - 10-24689-02 (132174)

    Johnson F4B-19 Impeller Pump - 24V - 48LPM - Heavy Duty - Self Priming - Bronze Body - 1/2" BSP, 1" Hose - 10-24689-02 (132174)

    Johnson F4B-19 Impeller Pump - Suits Bilge, Deckwash, Water Circulation, Oil and Diesel - Continuously Rated
    • Online Price: $580.00 (including 10 % GST tax)


    - OR -

    Australia's Best Price on Johnson F4B-19 Impeller Pump - 24V - 48LPM - 10-24689-02 (132174)

    Heavy Duty - Self Priming - Bronze Body - 1/2" BSP, 1" Hose

    overview

    Johnson F4B-19 Impeller Pump - 24V - 48LPM - 10-24689-02 (132174)

    Heavy Duty - Self Priming - Bronze Body - 1/2" BSP, 1" Hose

    Suits Bilge, Deckwash, Water Circulation, Oil and Diesel

    Reversible rubber impeller pump with integrated quick reversing switch. Designed to remove old oil from the engine/fill new oil back into the engine.

    Features:

    • Body: Bronze
    • Impeller: 09-824P-9
    • Seal: Lip seal
    • Connection: Hose 1" / ½" BSP
    • Length: 202mm
    • Width: 120mm
    • Height: 90mm
    • Weight: 3kg
    • Liquid temp.: Max +80°C
    • Motor: 0.12 kW, 12/24 V DC
    • The motor is ignition protected according to ISO 8846 (Small craft - Electrical devices - Protection against ignition of surrounding flammable gases).

    When the pump is used as bilge pump

    • Max total head 6 m. The pump must be installed so that the motor is protected from splash from bilge water.
    • The pump must be fitted with a strainer or other means of preventing debris from entering the pump.

    Self-priming

    • Pump is self-priming up to 3 m (for F4B 4 m). Intake lines must be air-tight to ensure self priming.
    • Note: Pump will prime when impeller is dry but suction lift up to 3 m (for F4B 4 m) is only obtainable when impeller is lubricated with liquid being pumped or Johnson Impeller lubricant.
    • For permanent installations where suction lift exceeds 4 m, a foot valve should be used to assure priming on start up.

    Continuous duty

    • For continuous duty 0,6 bar (60 kPa) maximum head is permissible. Normal working temperature of the motor may reach approx. +80°C (surface temperature) which may burn your skin.
    • The motor is equipped with built in thermal protection to prevent the motor from overheating. The protection is automatically restored when the motor is cooled.

    specification