BEP Marinco Tank Level Monitor Sender Interface Module - 600-TLM-SIF (113396)
overview
600-TLM-SIF - BEP Tank Level Monitor Sender Interface Module (113396)
Only required when using VDO or Centroid (10-180) ohm or SeaStar Solutions® (240-33) ohm senders to produce a 0-5V signal to operate the DCSM (113386). Switchable link for VDO or SeaStar Solutions® signal. 10-32V supply. One unit per sender is required.
The 600-TLM-SIF signal converter module is used to convert from 10-180 ohm, or 240-33 ohm tank sender outputs, to a 0-5V output. BEP equipment that uses a 0-5 volt signal input includes the DC Systems Monitor (DCSM), CZone Digital Switching/Monitoring, and the (obsolete) 600-TLM tank monitor.
specification
Supply voltage: 10-32 volts
Switchable jumper (link) for 240-33, or 10-180 ohm inputs
(Supplied with jumper set to suit 240-33 ohm senders)
Output voltage: 0-5 volts
60 x 34 x 22mm H (2.4" x 1.2" x 0.9" H)