BEP CZone Combination Output Interface (COI) - Combines Digital and Analogue Switching into One 30 Channel Waterproof Module for On-Screen Control 112912 (911-0119)
BEP CZone Combination Output Interface (COI) - Combines Digital and Analogue Switching into One 30 Channel Waterproof Module for On-Screen Control 112912 (911-0119)
-
Online Price: $2,538.00 (including 10 % GST tax)
- OR -
Australia's Best Price on BEP CZone Combination Output Interface 112912 (911-0119)
Combines Digital and Analogue Switching into One 30 Channel Waterproof Module for On-Screen Control
Digital Control and Monitoring Designed for Marine, Caravans and RV's
overview
BEP CZone Combination Output Interface 112912 (911-0119)
Combines Digital and Analogue Switching into One 30 Channel Waterproof Module for On-Screen Control
Digital Control and Monitoring Designed for Marine, Caravans and RV's
Digital Control and Monitoring (screen not included)
The CZone™ digital control & monitoring system is designed for manufacturers and installers of Marine, RV and Specialty Vehicles. It simplifies installation of electrical systems through the replacement of complicated, cumbersome wiring to switch and fuse panels, with state of the art, robust interfaces and light NMEA 2000 network cable. It also provides the end user a sophisticated solution through the automation of complicated control and monitoring issues associated with today’s on board systems.
Features:
- 16 x Output Channels (4 x 25A, 12 x 10A Dimmable)
- 8 x Analogue Inputs: Positive or Negative Switching, 0-32Volt, 0-1000 ohms resistance and 4-20mA Current
- 6 x Digital Inputs w Systems On/Backlighting via breakout harness
- 150A Maximum current
- Programmable software 'fuse' sizes, plus backup mechanical fuse and bypass on all circuits as required by ABYC/CE
- Complete CZone system in a box
- High Density 30 Channel module
- IPX5 water ingress protection
- Cost effective solution for a wide range of boats and recreational vehicles
- Simplified installation
- USB port provides easy upgrade path
- High power 150A unit drives "real world" 25A loads from a single channel
- Fully fused bypass on all circuits. Provides ultimate reliability and multiple layers of protection (software, hardware and mechanical)
- High power bilge pump channels allow manual control plus "pump running" feedback from a single channel - without additional wiring
- Power available LED feedback plus integrated supply voltage monitoring
- Manual fuse override indication
- NMEA voltage monitoring with network diagnostic tools
- Small footprint
- Optional cable cover
Cable protection (optional) and Fusing (included)
Downloads:
High Current and Low Current Outputs - Digital and Analogue Inputs - Optional Plug and Play (Deutsch)
Installation
Builders and installers recognize an immediate benefit with reductions in cable usage, harness weights and installation times. The CZone™ system also integrates many stand alone components into one intuitive system. Wiring is dramatically simplified, because the CZone™ system is designed to remove complex switching clusters and wiring runs. Integrated diagnostics ensures fault finding is simple. The CZone™ system is the digital networking system that is both cost-effective and scalable. Modules can easily be added into the system to best suit the builder's and end-users’ needs.
Traditional Electrical DC Wiring
Wiring DC systems can be complex and installation time can be extensive. The larger the system, the more wire is required, which creates weight and space concerns, not to mention increased cost and complexity of design and manufacturing. Basic maintenance and trouble shooting of traditional wiring systems can be difficult to manage.
- Switch panels use valuable console space
- Switch panel wiring is complicated and extremely labor intensive to install
- Cable runs are long and have multiple conductors. Switching of common circuits is complex
- Long wire runs require larger cable, adding weight, increasing cost and reducing space
Configuration
Integration - The CZone™ system is NMEA 2000 certified and uses the standard Micro cables and connectors. Being NMEA 2000 certified you can have trust in the network. This also allows a single network backbone to be installed for multiple systems (CZone™ and other NMEA 2000 devices). Additionally, the CZone™ system can share certain monitoring functions with other NMEA 2000 compliant screens.
DC Wiring
The CZone™ system decentralizes the DC power distribution system, locates circuit control and protection modules closer to loads to shorten cable runs and reduce the size of conductors, significantly decreasing the cost and weight of the electrical wiring harness. The system replaces complex wiring with a single data wire.
- Complex switch panel wiring removed, replaced with single data cable connection
- The grouping of multiple loads into common areas (Zones) with Output Interfaces is the key to the system
- Heavy-duty battery mains cable, replaced by multiple smaller conductors
Options:
- 112914 - CZone COI without Connectors
- 112912 - CZone COI with Connectors - Includes Deutsch plug connectors
- 112916 - CZone COI Cable Cover - Provides a clean finish by covering connectors and cables
- 112800 - CZone Touch 5 Control Display Screen
- 112824 - CZone Switch Control Interface
- 112828 - CZone Signal Interface
- 112820 - CZone Output Interface
- 112816 - CZone Motor Output Interface
- 112812 - CZone Meter Interface
specification
Total Channels |
30 Channels |
Output Channels High |
4 x 25A |
Output Channels Low |
12 x 10A Dimmable |
Analogue Inputs |
8 x Analogue Inputs: Positive or Negative Switching, 0-32 Volt, 0-1000 Ohm Resistance & 4-20mA Current |
Push Button Inputs |
6 x Digital Inputs w Systems On/Backlighting via breakout harness |
Circuit Current Monitoring |
Yes |
Circuit Protection |
Configurable Electronic Fuse + ATC Fuse |
Alarms |
Overcurrent, Short Circuit, Low Run Current, Fuse Tripped & Fuse In Over-ride alarms |
NMEA2000 PGN Output |
Fluid Level, Pressure, Temperature, Battery Volts |
Connectors |
Deutsch |
Maximum Current |
150A |
Power Supply |
M8 (5/16") Stud Positive, M6 (1/4") Negative |
Voltage |
9-32V (with Power Available LED and Voltage Monitoring) |
Circuit Bypass/Override |
Mechanical Protection/Bypass All Output Channels (Required by ABYC) |
Bilge Pump Circuits |
4 x Channels High: Integrated manual control & pump running detection |
Ingress Protection |
IPx5 (mounted at 0°, +/-90°) |
Communication |
NMEA 2000 |
Certification |
CE, ABYC, NMEA |
COI
COI with Optional Cable Cover